Adj Mega Par Profile Plus Bedienungsanleitung (16 Seiten) (2024)

Mega Par Profile Plus Safety Precautions

Power Supply: The ADJ Mega Par Prole Plus contains a automatic

voltage switch, which will auto sense the voltage when it is plugged

into the power source. With this switch there is no need to worry about

the correct power voltage, this unit can be plugged in anywhere.

DMX-512: DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures

and controllers. A DMX controller sends DMX data instructions from

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA

“OUT” terminal).

DMX Linking: DMX is a language allowing all makes and models of

dierent manufactures to be linked together and operate from a single

controller, as long as all xtures and the controller are DMX compli-

ant. To ensure proper DMX data transmission, when using several

DMX fixtures try to use the shortest cable path possible. The order

in which fixtures are connected in a DMX line does not influence the

DMX addressing. For example; a fixture assigned a DMX address of 1

may be placed anywhere in a DMX line, at the beginning, at the end,

or anywhere in the middle. When a fixture is assigned a DMX address

of 1, the DMX controller knows to send DATA assigned to address 1

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

The Mega Par Prole Plus can be controlled via DMX-512 protocol. The

Mega Par Prole Plus has 5 DMX modes, please see pages 9-10 for

the dierent modes. The DMX address is set on the back panel of the

Mega Par Prole Plus. Your unit and your DMX

controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We

recommend Accu-Cable DMX cables. If you are

making your own cables, be sure to use standard

110-120 Ohm shielded cable (This cable may be

purchased at almost all pro lighting stores). Your

cables should be made with a male and female

XLR connector on either end of the cable. Also

remember that DMX cable must be daisy chained

and cannot be split.

ADJ Products, LLC - www.adj.com - Mega Par Prole Plus User Manual Page 4

Mega Par Profile Plus DMX Set Up

ADJ Products, LLC - www.adj.com - Mega Par Prole Plus User Manual Page 5

To reduce the risk of electrical shock or re, do not expose this unit

rain or moisture

Do not spill water or other liquids into or on to your unit.

Do not attempt to operate this unit if the power cord has been

frayed or broken. Do not attempt to remove or break o the ground

prong from the electrical cord. This prong is used to reduce the risk

of electrical shock and re in case of an internal short.

Disconnect from main power before making any type of connection.

Do not remove the cover under any conditions. There are no user

serviceable parts inside.

Never operate this unit when it’s cover is removed.

Never plug this unit in to a dimmer pack

Always be sure to mount this unit in an area that will allow proper

ventilation. Allow about 6” (15cm) between this device and a wall.

Do not attempt to operate this unit, if it becomes damaged.

This unit is intended for indoor use only, use of this product out`

doors voids all warranties.

During long periods of non-use, disconnect the unit’s main power.

Always mount this unit in safe and stable matter.

Power-supply cords should be routed so that they are not likely to

be walked on or pinched by items placed upon or against them,

paying particular attention to the point they exit from the unit.

• Cleaning -The fixture should be cleaned only as recommended by

t he manufacturer. See page 24 for cleaning details.

Heat -The appliance should be situated away from heat sources

such as radiators, heat registers, stoves, or other appliances (inclu-

d ing amplifiers) that produce heat.

The fixture should be serviced by qualified service personnel when:

A. The power-supply cord or the plug has been damaged.

B. Objects have fallen, or liquid has been spilled into the appliance.

C. The appliance has been exposed to rain or water.

D. The appliance does not appear to operate normally or exhibits a

marked change in performance.

Figure 1

Adj Mega Par Profile Plus Bedienungsanleitung (16 Seiten) (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Velia Krajcik

Last Updated:

Views: 5653

Rating: 4.3 / 5 (54 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Velia Krajcik

Birthday: 1996-07-27

Address: 520 Balistreri Mount, South Armand, OR 60528

Phone: +466880739437

Job: Future Retail Associate

Hobby: Polo, Scouting, Worldbuilding, Cosplaying, Photography, Rowing, Nordic skating

Introduction: My name is Velia Krajcik, I am a handsome, clean, lucky, gleaming, magnificent, proud, glorious person who loves writing and wants to share my knowledge and understanding with you.